BIOSOFT™
Automatic aspiration device for histological biopsy
BIOSOFT™ is a disposable automatic aspiration device used in the main histological biopsies.
- Possibility to perform the biopsy with one hand, thanks to the presence of a spring that allows the sample to be taken automatically.
- Speed and certainty of biopsy performance.
- The particular sharpening of the tip enables users to obtain an integral sample, through a simple and non-traumatic penetration.
- The centimetre depth markings allow a safe positioning of the needle.
- The sliding stopper enables pre-definition of the penetration depth.
- Two versions are available:
– with a fixed cannula;
– with a removable cannula.
Major histological biopsies, such as those of the kidney, liver, and lungs, often require automatic aspiration biopsy systems to obtain high-quality tissue samples while minimizing bleeding, patient discomfort and complications.
- Kidney Biopsy: performed to diagnose kidney diseases, monitor transplant rejection, or assess disease progression. Typically done percutaneously using ultrasound or CT guidance with an automatic core biopsy needle, which ensures a precise and consistent sample.
- Liver Biopsy: used to evaluate liver conditions like hepatitis, cirrhosis, and tumours. Automatic aspiration (core) needles improve sample quality and reduce fragmentation, which is crucial for accurate histological analysis.
- Lung Biopsy: Essential for diagnosing lung cancer, infections, and interstitial lung diseases. CT-guided automatic biopsy devices provide rapid sample retrieval while minimizing lung trauma.
BIOSOFT™ allows for controlled, rapid tissue acquisition with minimal bleeding risk, making it a preferred choice for deep organ biopsies.
Surgical Technique:
- Load the needle by pressing the plunger until the anterior button is felt to engage.
- Insert the needle tip into the selected biopsy site and proceed under ultrasound guidance.
- Press the anterior firing button to start automatic aspiration. Advance the needle approximately 2 cm to take the sample.
- Slowly withdraw the needle.
- To retrieve the frustule near the needle tip, reload the device by pressing the rear plunger and deposit the sample on a slide.
GAUGE | DIAMETER (mm) | PRODUCT CODE WITH FIXED CANNULA | NEEDLE SIZE | PRODUCT CODE WITH REMOVABLE CANNULA | PIECES PER BOX |
16G | 1,60 | BSF1610C | 16G x 10cm | 10 | |
BSF1615C | 16G x 15cm | ||||
BSF1620C | 16G x 20cm | ||||
17G | 1,47 | BSF1710C | 17G x 10cm | 10 | |
BSF1715C | 17G x 15cm | ||||
BSF1720C | 17G x 20cm | ||||
18G | 1,27 | BSF1810C | 18G x 10cm | 10 | |
BSF1815C | 18G x 15cm | BSF1815C-GLP | |||
BSF1820C | 18G x 20cm | ||||
20G | 0,90 | BSF2010C | 20G x 10cm | 10 | |
BSF2015C | 20G x 15cm | ||||
BSF2020C | 20G x 20cm | ||||
21G | 0,80 | BSF2110C | 21G x 10cm | 10 | |
BSF2115C | 21G x 15cm | ||||
BSF2120C | 21G x 20cm | ||||
22G | 0,70 | BSF2210C | 22G x 10cm | BSF2210C-GLP | 10 |