Full view of the INTRODUTTORE coaxial biopsy needle, an essential tool for efficient and minimally invasive multiple tissue sampling.

INTRODUTTORE™

Coaxial positioning needle

Coaxial needle recommended in soft tissue biopsies with multiple samples.
  • Fegato
  • Pancreas
  • Polmoni
  • Reni
  • Seno

INTRODUTTORE™ (or coaxial needle) is positioned to identify the exact area to be analysed. The biopsy needle is then inserted through the coaxial cannula.

  • Sharpened Trocar tip.
  • Transparent conical grip.
  • Extra-thin wall tubing.
  • Colour-coded stopper.
  • Centimeter markings.
  • Available as a standalone device or as an additional option for biopsy needles such as SPEEDYBELL™, SPEEDYBELL DOPPIA CORSA™ and ESTER™/ESTER ONE SHOT™

Soft tissue biopsies that require multiple samples are typically performed when a more comprehensive tissue analysis is needed to improve diagnostic accuracy.

Taking multiple samples increases the likelihood of capturing representative tissue.

With the coaxial biopsy technique, a coaxial introducer needle allows multiple passes with a biopsy needle without re-puncturing the skin, reducing trauma and procedure time.

Surgical technique:

  • Insert the INTRODUTTORE™ needle into the target tissue to establish the biopsy pathway.
  • Confirm correct positioning under imaging guidance.
  • Insert the biopsy needle through the coaxial cannula to obtain multiple samples without repositioning.
  • Once sampling is complete, carefully remove the needle while maintaining control of the biopsy site.
GAUGE DIAMETER (mm) LENGTH (mm) CODE
14G 2,25 50

100

150

200

STR1405EC

STR1410EC

STR1415EC

STR1420EC

16G 1,85 50

100

150

200

STR1605EC

STR1610EC

STR1615EC

STR1620EC

18G 1,55 50

100

150

200

STR1805EC

STR1810EC

STR1815EC

STR1820EC

20G 1,15 50

100

150

200

STR2005EC

STR2010EC

STR2015EC

STR2020EC

RELATED PRODUCTs

Automatic device for soft tissue biopsy
Semi-automatic guillotine needle for soft tissue biopsy
Semi-automatic guillotine needle for soft tissue biopsy with 10 mm or 20 mm collection area

Fill out the form below, one of our expert will get in touch with you shortly!

Notice reserved for healthcare professionals

The content of this website is intended exclusively for healthcare professionals.
In accordance with current regulations (Legislative Decree 46/97 and EU Regulation 2017/745), access to information related to medical devices is restricted to healthcare professionals only.

I declare that I am a healthcare professional.